Battery Maintenance – Implementation Details
This document describes the internal structure, helpers, scripts, automations, and UI used to implement the battery maintenance system.
Architecture Overview
The system is built around a central controller script, supported by dedicated phase scripts and a shared set of helpers.
User / Automation
↓
Confirmation Script
↓
Battery Maintenance – Controller
↓
┌───────────────┬────────────────┬────────────────┐
│ Discharge │ Charge │ Restore │
│ to 15% │ to 100% │ Backup Mode │
└───────────────┴────────────────┴────────────────┘Scripts
1. Battery Maintenance – Controller
Role: Orchestrates the full maintenance cycle.
Responsibilities:
- Prevents concurrent execution
- Initializes helpers
- Starts discharge and charge phases
- Waits for SOC thresholds using
wait_for_trigger - Handles timeouts and error conditions
- Stops cleanly on cancellation
- Marks completion and updates timestamps
Key characteristics:
mode: single- Uses
input_boolean.battery_maintenance_activeas a cancel signal - Uses
input_select.battery_maintenance_phaseas the system state machine
2. Battery Maintenance – Cancel
Role: Safe, idempotent cancellation and cleanup.
Design goals:
- Safe to run multiple times
- Never depends on
battery_maintenance_activebeing ON - Guarantees battery restore
Behavior:
- If phase is already
cancelled, exit immediately - Mark phase as
cancelled - Turn off
battery_maintenance_active - Restore 50% backup reservation
- Notify user
This ensures no repeated Modbus writes and no partial restores.
3. Discharge Backup Battery to 15%
Role: Configures inverter for controlled discharge.
Actions:
- Sets phase to
discharging - Records phase start timestamp
- Disables reserve mode
- Sets discharge limit to 15%
- Enables discharge mode
This script only performs hardware configuration. All monitoring is handled by the controller.
4. Charge Backup Battery to 100%
Role: Configures inverter for full charge.
Actions:
- Sets phase to
charging - Records phase start timestamp
- Disables discharge mode
- Enables charging mode
5. Restore 50% Backup Mode
Role: Return inverter to normal operating mode.
Actions:
- Sets phase to
restoring - Records phase start timestamp
- Disables maintenance-specific modes
- Restores 50% backup reservation
This script is intentionally safe to re-run if needed.
Helpers (Detailed)
input_boolean.battery_maintenance_active
- ON → maintenance running
- OFF → cancel requested or maintenance finished
- Observed by controller
wait_for_trigger
input_select.battery_maintenance_phase
Acts as a state machine and UI signal.
Typical values:
- starting
- discharging
- discharge_delay
- charging
- charge_delay
- restoring
- cancelled
- completed
- error
This helper is the authoritative system state.
input_datetime.battery_maintenance_phase_start_time
- Automatically set using
input_datetime.set_datetime - Represents the local timestamp of the current phase start
- Used for:
- elapsed time display
- progress estimation
- diagnostics
Automations
Scheduled Maintenance Automation
- Triggers weekly (or manually)
- Calls confirmation script
- Does not directly start maintenance
This ensures accidental runs are avoided.
User Interface (Dashboard)
The dashboard provides:
- Current phase display
- Phase elapsed time
- Start / Cancel buttons
- Last maintenance timestamp
- Real-time SOC monitoring
UI elements are bound directly to helpers, making state transparent.
Error Handling & Timeouts
Each phase:
- Uses
wait_for_triggerwith SOC thresholds - Includes a generous timeout
- On timeout:
- Phase is set to
error - Cancel script is executed
- Battery is restored safely
- Phase is set to
Restart Safety
If Home Assistant restarts mid-maintenance:
- Helpers retain last known state
- User can run Battery Maintenance – Cancel
- System returns to a safe configuration
Design Rationale
Key decisions:
- Cancel logic based on phase, not boolean
- Controller handles logic, phase scripts handle hardware
- Idempotency prioritized over brevity
- Explicit helpers preferred over implicit state
Future Improvements (Optional)
- Modbus write deduplication
- Resume logic after restart
- Maintenance statistics (cycle count, durations)
- Alerting if scheduled run is skipped